Monthly Archives: February 2020

DWM-HEXADUO AIR PURIFIER USER GUIDE

DWM-HexaDuo Air Purifier is easy to use, and helps to produce a clean and safe enviroment. It’s an energy-efficient high performance air purifier The Size is compact enough to place in anywhere.

1.Packing list

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-package-list

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-package-list

2.Components

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-components

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-components

3.Operations

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-operation

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-operation

3.1 Operation Modes

3.1.1 Clean Mode

When the accumulated operation time reach two weeks,The cleaning

indicatorcleaning-indicatorwill be lights up to remind the user to clean the collection array.

Press thefan-speed-press fan speed level button for 3sec to acknowledge the cleaning alert. The cleaning inducator buttton will be turn off.Power off the unit and take out collection array to clean.Clean and dry the collection array before re-install back to the device.

3.1.2 Protection Mode

When the device is operating, and the collection array is removed suddenly, then the device will be stop working, and all indicators will flash at the same time as an alert to user.when the device is powered on without the collection array the device will not work, and all Indicators will flash at the same time as an alert to user. the user needs to shut down the device, and put the collection array into the device, and then the unit will return to nomal operation mode.

3.1.3 Failure Mode

When the collection array accumulates dust anvil or debris and over the collection limit, the device will be stop operation, and all of te lights will flash at the same time as alert to user.The user will need to shut down the device and clean the collection array.

4.Instructions

4.1 connect the power adptor

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-connect-power

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-connect-power

Note:

In order to have better effect of air purification, the circular clearance area should be 1.6ft(0.5m) in radius when the device is placed at the center.

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-room

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-room

4.2 Turn On the device

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-power-on

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-power-on

Note:

You may hear static noise when the unit is first time started, This is nomal due to setting up of the electrostatic field for capturing the air borne particles.

4.3 Adjust the required speed

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE change-fan-speed

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE change-fan-speed

Note:

“Turbo Fan Mode” is a 20-min turbo cleaning setting that rapidly purify the air with its maximum power in shortest possiable time, the fan speed will then resume to low level for power saving and silent operations.

4.4 Stretch the bipod of the unit and put the unit on a flat table or floor.

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-set

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-set

4.Clean and Maintenance

4.1 Power off the unit and turn the collection array upright to unlock and then remove it from the unit.

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-open-clean

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-open-clean

4.2 For strong or sticky oil type pollutant,spray soft cleaner and use cleaning tool to clean the individual dust plate.

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-maintenance-clean

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-maintenance-clean

4.3 Immerse the whole collection array into water or rines the collection array throroughly under running water.

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-open-clean-1

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-open-clean-1

4.4 Dry the collection array before re-install it back to the unite,install the collection array in vertical direction and then turn to desire air flow angle and lock it.

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-maintenance-clean-1

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-maintenance-clean-1

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-note

dwm-hexaduo-air-purifier-washable-electrostatic-filter-kills-airborne-bacteria-note

5 Trouble shooting

Not Operating ,No light indication

-Ensure the collection array is connected with the fan body firmly.

-Ensure the AC adaptor is fully inserted into the AC outlet and its plug is connected to the DC jack of the air purifier.

-Press the Power button momentarily to observe that it’s light up.

Not operating,indicator flashing

-Check the collection array, for too heavy dirt or any clogging by hairs or fibers.

-Clean the collection array as needed and install back ion the air purifier.

If you want buy one pls visit our online shop DWM-HexaDuo Air Purifier .

DWM-HEXAONE AIR PURIFIER USER GUIDE

DWM-HEXAONE AIR PURIFIER is easy to use, and helps to produce a clean and safe enviroment. It’s an energy-efficient high performance air purifier The Size is compact enough to place in anywhere.

1.Packing list

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-package

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-package

2.Components

WM-HEXAONE-AIR-PURIFIER-USER-GUIDE-Componets

3.Operations

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-operation

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-operation

3.1 Operation Modes

3.1.1 Clean Mode

When the accumulated operation time reach two weeks,The cleaning

indicatorcleaning-indicatorwill be lights up to remind the user to clean the collection array.

Press thefan-speed-press fan speed level button for 3sec to acknowledge the cleaning alert. The cleaning inducator buttton will be turn off.Power off the unit and take out collection array to clean.Clean and dry the collection array before re-install back to the device.

3.1.2 Protection Mode

When the device is operating, and the collection array is removed suddenly, then the device will be stop working, and all indicators will flash at the same time as an alert to user.when the device is powered on without the collection array the device will not work, and all Indicators will flash at the same time as an alert to user. the user needs to shut down the device, and put the collection array into the device, and then the unit will return to nomal operation mode.

3.1.3 Failure Mode

When the collection array accumulates dust anvil or debris and over the collection limit, the device will be stop operation, and all of te lights will flash at the same time as alert to user.The user will need to shut down the device and clean the collection array.

4.Instructions

4.1 connect the power adptor

 

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-connect-adapter

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-connect-adapter

Note:

In order to have better effect of air purification, the circular clearance area should be 1.6ft(0.5m) in radius when the device is placed at the center.

DWM-HEXAONE-circular-clearance-area

DWM-HEXAONE-circular-clearance-area

4.2 Turn On the device

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-power-on

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-power-on

Note:

You may hear static noise when the unit is first time started, This is nomal due to setting up of the electrostatic field for capturing the air borne particles.

4.3 Adjust the required speed

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE change-fan-speed

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE change-fan-speed

Note:

“Turbo Fan Mode” is a 20-min turbo cleaning setting that rapidly purify the air with its maximum power in shortest possiable time, the fan speed will then resume to low level for power saving and silent operations.

4.4 Adjust the Air flow direction.

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-adjust-direction

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-adjust-direction

5.Clean and Maintenance

5.1 Power off the unit and turn the collection array upright to unlock and then remove it from the unit.

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-clean-maintenance

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-clean-maintenance

5.2 For strong or sticky oil type pollutant,spray soft cleaner and use cleaning tool to clean the individual dust plate.

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-clean

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-clean

5.3 Immerse the whole collection array into water or rines the collection array throroughly under running water.

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-clean-1

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-clean-1

5.4 Dry the collection array before re-install it back to the unite,install the collection array in vertical direction and then turn to desire air flow angle and lock it.

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-maintenance

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-maintenance

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-note

DWM-HEXAONE-AIR-PURIFIER-USER-GUIDE-note

6 Trouble shooting

Not Operating ,No light indication

-Ensure the collection array is connected with the fan body firmly.

-Ensure the AC adaptor is fully inserted into the AC outlet and its plug is connected to the DC jack of the air purifier.

-Press the Power button momentarily to observe that it’s light up.

Not operating,indicator flashing

-Check the collection array, for too heavy dirt or any clogging by hairs or fibers.

-Clean the collection array as needed and install back ion the air purifier.

If you want buy one pls visit our online shop DWM-HEXAONE AIR PURIFIER .

 

DWM-HC1230 FSK Transmitters module Datasheet

DWM-HC1230 is a FSK Transmitters module which build by Sx1230 chipset for more details about the Sx1230 you can visit the link: sx1230datasheet .

1.DWM-HC1230 Pin Diagram

dwm-hc1230-semtech-sx1230-433mhz-868mhz-915mhz-small-size-smd-package-transmitter-PIN-DIAGRAM

dwm-hc1230-semtech-sx1230-433mhz-868mhz-915mhz-small-size-smd-package-transmitter-PIN-DIAGRAM

2.Pin Description

PIN No.  Name I/O/P Description
 1 RESET  I/O Reset, active high
 2  NC  —  —
 3  PB0  I Low battery indicator output
 4 CLKOUT O Reference clock output for MCU
 5,14,15 GND O Ground
 6  VDD P Module Power supply Positive
 7 DCLK  O Output data clock
 8  SCK  I SPI clock input
 9 MISO  I/O SPI Data input and SPI Data output
 10 MOSI I/O SPI Data output and SPI Data input
 11 NSS  I/O SPI Chip select input and SPI Chip Select output
 12 DATA  I Modulation input data
 13  ANT O  Module Antenna terminal, Option termina
 16  ANT O  Module Antenna terminal, Default termina

3.Reference Design

3.1 DWM-HC1230 E 2 PROM Mode Application Circuit

dwmzone-DWM-HC1230-E-2-PROM-Mode-Application-Circuit

dwmzone-DWM-HC1230-E-2-PROM-Mode-Application-Circuit

3.2 DWM-HC1230 MCU Mode Application Circuit

dwmzone-DWM-HC1230-mcu-Mode-Application-Circuit

dwmzone-DWM-HC1230-mcu-Mode-Application-Circuit

4.Packaging Information(unit:mm)

dwm-hc1230-semtech-sx1230-433mhz-868mhz-915mhz-small-size-smd-package-transmitter-package

dwm-hc1230-semtech-sx1230-433mhz-868mhz-915mhz-small-size-smd-package-transmitter-package

5. Demo code

DWM-HC1230_AK001_demo

CTT180610647ENA ROHS

CTT180610647ENB REACH

DWM-LJ1276 LoRa transceiver RF module Datasheet

DWM-LJ1276 is LoRa transceiver RF module which build by Sx1276 chipset for more details about the Sx1276 you can visit the link: sx1276datasheet .

1.DWM-LJ1276 PIN Diagram

DWM-JL1276-datasheet-pin-dagram

DWM-JL1276-datasheet-pin-dagram

2.Pin Description

PIN No.  Name I/O/P Description
 1  GND  I  Ground
 2   MISO  O  SPI Data output
 3  MOSI  I  SPI Data input
 4  SCK  I  SPI Clock input
 5  NSS  I  SPI Chip select input
 6  RESET  I  Reset trigger input
 7  DIO5  I/O  Digital I/O, software configured
 8  GND  I  Ground
 9  ANT  O  RF Output
 10  GND  I  Ground
 11  DIO3  I/O  Digital I/O, software configured
 12  DIO4  I/O  Digital I/O, software configured
 13  VCC  I  Supply voltage for moudule
 14  DIO0  I/O  Digital I/O, software configured
 15  DIO1  I/O  Digital I/O, software configured
 16  DIO2  I/O  Digital I/O, software configured

3.Reference Design

DWM-JL1276-datasheet-reference-design

DWM-JL1276-datasheet-reference-design

3.1 BOM of Typical Application

Designator Description Manufacturer
 M1  Module LJ1295 16*16*1.8mm RoHS  Dwmzone
 U1  IC 8 BIT MCU STM8S003F3 SSOP20 RoHS  MICROICHIP
 U2  IC LDO XC6206P33PR 3.3V SOT-23 RoHS  TOREX
 L1  Thick film resistor0R 5% 1/16W 0402 RoHS  ROHM
 C1  NC
 C2  NC
 C3  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA
 C4  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA
 C5  CAP CER 10uF/16V 20% X5R 0402 RoHS  MURATA
 C6  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA
 C7  CAP CER 47uF/16V 20% X5R 1206 RoHS  MURATA
 C8  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA

4.Example CRC Calculation

The following routine(s) may be implemented to mimic the CRC calculation of the DWM-LJ1276.

DWM-JL1295--LJ1276-datasheet-Example-CRC-Calculation

DWM-JL1295–LJ1276-datasheet-Example-CRC-Calculation

5.Example Temperature Reading

The following routine(s) may be implemented to read the temperature and calibrate the sensor.

DWM-JL1295-LJ1276-datasheet-Example-Temperature-reading

DWM-JL1295-LJ1276-datasheet-Example-Temperature-reading

6.Packaging Information(unit:mm)

6.1 The Size of the PCB board.

DWM-JL1276-datasheet-packaging

6.2 The Size of the Shielding case

7.Recommended PCB Land Pattern (unit:mm)

DWM-JL1276-datasheet-Recommended-PCB-Land-Pattern

DWM-JL1276-datasheet-Recommended-PCB-Land-Pattern

8. Demo code

DWM-1276 DEMO

CTT180610647ENA ROHS

CTT180610647ENB REACH

DDT-R19050915-1E1 LJ1276-868 EN 301489-1-3 Report

DDT-R19050915-1E2 LJ1276-868 EN 300 220 Report 868MHz

DDT-R19050915-1E3 LJ1276-868 EN 62479 Report

 

If you want to get the samples pls visit the online shop DWM-LJ1276.

DWM-LJ1295 LoRa transceiver RF module Datasheet

DWM-LJ1295 is LoRa transceiver RF module which build by Sx1276 chipset for more details about the Sx1276 you can visit the link: sx1276datasheet .

1.DWM-LJ1295 PIN Diagram

DWM-JL1295-datasheet-pin-dagram

DWM-JL1295-datasheet-pin-dagram

2.Pin Description

PIN No.  Name I/O/P Description
 1  GND  I  Ground
 2   MISO  O  SPI Data output
 3  MOSI  I  SPI Data input
 4  SCK  I  SPI Clock input
 5  NSS  I  SPI Chip select input
 6  RESET  I  Reset trigger input
 7  DIO5  I/O  Digital I/O, software configured
 8  GND  I  Ground
 9  ANT  O  RF Output
 10  GND  I  Ground
 11  DIO3  I/O  Digital I/O, software configured
 12  DIO4  I/O  Digital I/O, software configured
 13  VCC  I  Supply voltage for moudule
 14  DIO0  I/O  Digital I/O, software configured
 15  DIO1  I/O  Digital I/O, software configured
 16  DIO2  I/O  Digital I/O, software configured

3.Reference Design

DWM-JL1295-datasheet-reference-design

DWM-JL1295-datasheet-reference-design

3.1 BOM of Typical Application

Designator Description Manufacturer
 M1  Module LJ1295 16*16*1.8mm RoHS  Dwmzone
 U1  IC 8 BIT MCU STM8S003F3 SSOP20 RoHS  MICROICHIP
 U2  IC LDO XC6206P33PR 3.3V SOT-23 RoHS  TOREX
 L1  Thick film resistor0R 5% 1/16W 0402 RoHS  ROHM
 C1  NC
 C2  NC
 C3  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA
 C4  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA
 C5  CAP CER 10uF/16V 20% X5R 0402 RoHS  MURATA
 C6  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA
 C7  CAP CER 47uF/16V 20% X5R 1206 RoHS  MURATA
 C8  CER 0.1uF/25V 20% X7R 0402 RoHS  MURATA

4.Example CRC Calculation

The following routine(s) may be implemented to mimic the CRC calculation of the DWM-LJ1295.

DWM-JL1295-datasheet-Example-CRC-Calculation

DWM-JL1295-datasheet-Example-CRC-Calculation

5.Example Temperature Reading

The following routine(s) may be implemented to read the temperature and calibrate the sensor.

DWM-JL1295-datasheet-Example-Temperature-reading

DWM-JL1295-datasheet-Example-Temperature-reading

6.Packaging Information

DWM-JL1295-datasheet-packaging

DWM-JL1295-datasheet-packaging

7.Recommended PCB Land Pattern

8. Demo code

 DWM-LJ1295 Demo code

CTT180610647ENA ROHS

CTT180610647ENB REACH

If you want to get the samples pls visit the online shop DWM-LJ1295.